CE-Mark Planning Checklist

Scoring System

Total Score: 0 to 42

  • 0Not started or missing
  • 1In progress or incomplete
  • 2Complete & verified or not applicable

General Regulatory Preparedness

Have you determined the correct device classification (Class I, IIa, IIb, III)?

Regulators reference: MDR Annex VIII

Is your intended purpose clearly defined and aligned across all documents?

Regulators reference: MDR article 2(12), Annex I

Have you appointed a PRRC (Person Responsible for Regulatory Compliance)?

MDR Article 15

Have you identified your conformity assessment route?

MDR Annexes IX–XI

If applicable, have you engaged with a suitable notified body?

MDR Article 52

Technical Documentation (Annex II & III)

Is your device description section complete with variants, accessories, and UDI?

Annex II, Section 1

Are your risk management file, clinical evaluation, and post-market surveillance interlinked?

Annex I, Chapter I & Annex II

Are your design and manufacturing processes fully documented and traceable?

Annex II, Section 3

Have you completed your General Safety and Performance Requirements (GSPR) checklist with traceable evidence for supporting each criterion?

Annex II, Section 4.1

Clinical Evaluation & PMS Planning

Is your Clinical Evaluation Report (CER) compliant with Annex XIV & MDCG 2020-13?

Annex XIV Part A

Have you completed a robust literature review or clinical investigation (if required)?

Annex XIV

Is a PMCF Plan prepared and justified?

Annex XIV Part B & MDCG 2020-7

Are your PMS Plan and PSUR/SSCP aligned with Article 83 and Article 86-87?

Articles 83–86

QMS Alignment (ISO 13485 + MDR Requirements)

Is your ISO 13485:2016 certificate up-to-date and includes MDR-specific processes?

Article 10(9)

Are roles, responsibilities, and training documented and traceable?

Annex IX / ISO 13485 Clause 6

Are CAPA, complaints, vigilance, and field safety processes integrated in QMS?

Annex III / Article 87

Is your supplier control documented and risk-based?

Annex II, Section 3 / ISO 13485 Clause 7.4

Labelling, UDI & EUDAMED

Are labels, IFUs, and packaging validated and compliant with MDR Annex I, Section 23?

Annex I, Chapter III

Is Basic UDI-DI assigned and correctly used across all documentation?

Article 27 / Annex VI Part C

Are you registered as a manufacturer in EUDAMED (or prepared to do so)?

Article 29

Have you prepared and formatted your SSCP (if Class III or implantable)?

Article 32 / MDCG 2019-9

Result

Critical Risk

Immediate regulatory support needed

Moderate Risk

Review and close gaps before NB engagement

Almost Ready

Final review recommended

Strong Foundation!

Consult with regulatory partner to prepare for final review and regulatory alignment

Contact Now!

Right here at the booth to help you!

  • Heike Schön

    Heike Schön
    Founder and CEO

  • Liam Spencer

    Liam Spencer
    Head of Regulatory Services

  • Lars Bak Christensen

    Lars Bak-Christensen
    Business Development Manager

  • Nasim Moradi

    Nasim Moradi
    Marketing and Team Assistant

Disclaimer

This checklist is intended for informational and internal planning purposes only. It is not a regulatory validation tool, nor does it constitute a complete assessment of conformity under Regulation (EU) 2017/745. Completion of this checklist does not confirm regulatory compliance or readiness for CE-marking submission.

For a complete and reliable regulatory evaluation, we strongly recommend engaging a qualified regulatory professional. Lumis International GmbH accepts no responsibility for decisions made on this preliminary tool without formal consultation.